Networking with neutron
|
|
=======================
|
|
|
|
While nova uses the :neutron-doc:`OpenStack Networking service (neutron) <>` to
|
|
provide network connectivity for instances, nova itself provides some
|
|
additional features not possible with neutron alone. These are described below.
|
|
|
|
|
|
SR-IOV
|
|
------
|
|
|
|
.. versionchanged:: 2014.2
|
|
|
|
The feature described below was first introduced in the Juno release.
|
|
|
|
The SR-IOV specification defines a standardized mechanism to virtualize PCIe
|
|
devices. This mechanism can virtualize a single PCIe Ethernet controller to
|
|
appear as multiple PCIe devices. Each device can be directly assigned to an
|
|
instance, bypassing the hypervisor and virtual switch layer. As a result, users
|
|
are able to achieve low latency and near-line wire speed.
|
|
|
|
A full guide on configuring and using SR-IOV is provided in the
|
|
:neutron-doc:`OpenStack Networking service documentation
|
|
<admin/config-sriov.html>`
|
|
|
|
.. note::
|
|
|
|
Nova only supports PCI addresses where the fields are restricted to the
|
|
following maximum value:
|
|
|
|
* domain - 0xFFFF
|
|
* bus - 0xFF
|
|
* slot - 0x1F
|
|
* function - 0x7
|
|
|
|
Nova will ignore PCI devices reported by the hypervisor if the address is
|
|
outside of these ranges.
|
|
|
|
.. versionadded:: 25.0.0
|
|
|
|
For information on creating servers with remotely-managed SR-IOV network
|
|
interfaces of SmartNIC DPUs, refer to the relevant section in
|
|
:neutron-doc:`Networking Guide <admin/ovn/smartnic_dpu>`.
|
|
|
|
**Limitations**
|
|
|
|
* Only VFs are supported and they must be tagged in the Nova Compute
|
|
configuration in the :oslo.config:option:`pci.device_spec` option as
|
|
``remote_managed: "true"``. There is no auto-discovery of this based
|
|
on vendor and product IDs;
|
|
* Either VF or its respective PF must expose a PCI VPD capability with a
|
|
unique card serial number according to the PCI/PCIe specifications
|
|
(see `the Libvirt docs <https://libvirt.org/drvnodedev.html#VPDCap>`_ to
|
|
get an example of how VPD data is represented and what to expect). If
|
|
this is not the case, those devices will not appear in allocation pools;
|
|
* Only the Libvirt driver is capable of supporting this feature at the
|
|
time of writing;
|
|
* The support for VPD capability handling in Libvirt was added in release
|
|
`7.9.0 <https://libvirt.org/news.html#v7-9-0-2021-11-01>`_ - older
|
|
versions are not supported by this feature;
|
|
* All compute nodes must be upgraded to the Yoga release in order for
|
|
scheduling of nodes with ``VNIC_TYPE_REMOTE_MANAGED`` ports to succeed;
|
|
* The same limitations apply to operations like live migration as with
|
|
`legacy SR-IOV ports <https://docs.openstack.org/neutron/latest/admin/config-sriov.html#known-limitations>`_;
|
|
* Clearing a VLAN by programming VLAN 0 must not result in errors in the
|
|
VF kernel driver at the compute host. Before v8.1.0 Libvirt clears
|
|
a VLAN by programming VLAN 0 before passing a VF through to the guest
|
|
which may result in an error depending on your driver and kernel version
|
|
(see, for example, `this bug <https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1957753>`_
|
|
which discusses a case relevant to one driver). As of Libvirt v8.1.0,
|
|
EPERM errors encountered while programming VLAN 0 are ignored if
|
|
VLAN clearing is not explicitly requested in the device XML (i.e.
|
|
VLAN 0 is not specified explicitly).
|
|
|
|
NUMA Affinity
|
|
-------------
|
|
|
|
.. versionadded:: 18.0.0
|
|
|
|
The feature described below was first introduced in the Rocky release.
|
|
|
|
.. important::
|
|
|
|
The functionality described below is currently only supported by the
|
|
libvirt/KVM driver.
|
|
|
|
As described in :doc:`cpu-topologies`, NUMA is a computer architecture where
|
|
memory accesses to certain regions of system memory can have higher latencies
|
|
than other regions, depending on the CPU(s) your process is running on. This
|
|
effect extends to devices connected to the PCIe bus, a concept known as NUMA
|
|
I/O. Many Network Interface Cards (NICs) connect using the PCIe interface,
|
|
meaning they are susceptible to the ill-effects of poor NUMA affinitization. As
|
|
a result, NUMA locality must be considered when creating an instance where high
|
|
dataplane performance is a requirement.
|
|
|
|
Fortunately, nova provides functionality to ensure NUMA affinitization is
|
|
provided for instances using neutron. How this works depends on the type of
|
|
port you are trying to use.
|
|
|
|
For SR-IOV ports, virtual functions, which are PCI devices, are attached to the
|
|
instance. This means the instance can benefit from the NUMA affinity guarantees
|
|
provided for PCI devices. This happens automatically and is described in detail
|
|
in :ref:`pci-numa-affinity-policy`.
|
|
|
|
For all other types of ports, some manual configuration is required.
|
|
|
|
#. Identify the type of network(s) you wish to provide NUMA affinity for.
|
|
|
|
- If a network is an L2-type network (``provider:network_type`` of ``flat``
|
|
or ``vlan``), affinity of the network to given NUMA node(s) can vary
|
|
depending on value of the ``provider:physical_network`` attribute of the
|
|
network, commonly referred to as the *physnet* of the network. This is
|
|
because most neutron drivers map each *physnet* to a different bridge, to
|
|
which multiple NICs are attached, or to a different (logical) NIC.
|
|
|
|
- If a network is an L3-type networks (``provider:network_type`` of
|
|
``vxlan``, ``gre`` or ``geneve``), all traffic will use the device to
|
|
which the *endpoint IP* is assigned. This means all L3 networks on a given
|
|
host will have affinity to the same NUMA node(s). Refer to
|
|
:neutron-doc:`the neutron documentation
|
|
<admin/intro-overlay-protocols.html>` for more information.
|
|
|
|
#. Determine the NUMA affinity of the NICs attached to the given network(s).
|
|
|
|
How this should be achieved varies depending on the switching solution used
|
|
and whether the network is a L2-type network or an L3-type networks.
|
|
|
|
Consider an L2-type network using the Linux Bridge mechanism driver. As
|
|
noted in the :neutron-doc:`neutron documentation
|
|
<admin/deploy-lb-selfservice.html>`, *physnets* are mapped to interfaces
|
|
using the ``[linux_bridge] physical_interface_mappings`` configuration
|
|
option. For example:
|
|
|
|
.. code-block:: ini
|
|
|
|
[linux_bridge]
|
|
physical_interface_mappings = provider:PROVIDER_INTERFACE
|
|
|
|
Once you have the device name, you can query *sysfs* to retrieve the NUMA
|
|
affinity for this device. For example:
|
|
|
|
.. code-block:: shell
|
|
|
|
$ cat /sys/class/net/PROVIDER_INTERFACE/device/numa_node
|
|
|
|
For an L3-type network using the Linux Bridge mechanism driver, the device
|
|
used will be configured using protocol-specific endpoint IP configuration
|
|
option. For VXLAN, this is the ``[vxlan] local_ip`` option. For example:
|
|
|
|
.. code-block:: ini
|
|
|
|
[vxlan]
|
|
local_ip = OVERLAY_INTERFACE_IP_ADDRESS
|
|
|
|
Once you have the IP address in question, you can use :command:`ip` to
|
|
identify the device that has been assigned this IP address and from there
|
|
can query the NUMA affinity using *sysfs* as above.
|
|
|
|
.. note::
|
|
|
|
The example provided above is merely that: an example. How one should
|
|
identify this information can vary massively depending on the driver
|
|
used, whether bonding is used, the type of network used, etc.
|
|
|
|
#. Configure NUMA affinity in ``nova.conf``.
|
|
|
|
Once you have identified the NUMA affinity of the devices used for your
|
|
networks, you need to configure this in ``nova.conf``. As before, how this
|
|
should be achieved varies depending on the type of network.
|
|
|
|
For L2-type networks, NUMA affinity is defined based on the
|
|
``provider:physical_network`` attribute of the network. There are two
|
|
configuration options that must be set:
|
|
|
|
``[neutron] physnets``
|
|
This should be set to the list of physnets for which you wish to provide
|
|
NUMA affinity. Refer to the :oslo.config:option:`documentation
|
|
<neutron.physnets>` for more information.
|
|
|
|
``[neutron_physnet_{physnet}] numa_nodes``
|
|
This should be set to the list of NUMA node(s) that networks with the
|
|
given ``{physnet}`` should be affinitized to.
|
|
|
|
For L3-type networks, NUMA affinity is defined globally for all tunneled
|
|
networks on a given host. There is only one configuration option that must
|
|
be set:
|
|
|
|
``[neutron_tunnel] numa_nodes``
|
|
This should be set to a list of one or NUMA nodes to which instances using
|
|
tunneled networks will be affinitized.
|
|
|
|
#. Configure a NUMA topology for instance flavor(s)
|
|
|
|
For network NUMA affinity to have any effect, the instance must have a NUMA
|
|
topology itself. This can be configured explicitly, using the
|
|
``hw:numa_nodes`` extra spec, or implicitly through the use of CPU pinning
|
|
(``hw:cpu_policy=dedicated``) or PCI devices. For more information, refer to
|
|
:doc:`cpu-topologies`.
|
|
|
|
Examples
|
|
~~~~~~~~
|
|
|
|
Take an example for deployment using L2-type networks first.
|
|
|
|
.. code-block:: ini
|
|
|
|
[neutron]
|
|
physnets = foo,bar
|
|
|
|
[neutron_physnet_foo]
|
|
numa_nodes = 0
|
|
|
|
[neutron_physnet_bar]
|
|
numa_nodes = 2, 3
|
|
|
|
This configuration will ensure instances using one or more L2-type networks
|
|
with ``provider:physical_network=foo`` must be scheduled on host cores from
|
|
NUMA nodes 0, while instances using one or more networks with
|
|
``provider:physical_network=bar`` must be scheduled on host cores from both
|
|
NUMA nodes 2 and 3. For the latter case, it will be necessary to split the
|
|
guest across two or more host NUMA nodes using the
|
|
:nova:extra-spec:`hw:numa_nodes` extra spec, as discussed :ref:`here
|
|
<numa-topologies>`.
|
|
|
|
Now, take an example for a deployment using L3 networks.
|
|
|
|
.. code-block:: ini
|
|
|
|
[neutron_tunnel]
|
|
numa_nodes = 0
|
|
|
|
This is much simpler as all tunneled traffic uses the same logical interface.
|
|
As with the L2-type networks, this configuration will ensure instances using
|
|
one or more L3-type networks must be scheduled on host cores from NUMA node 0.
|
|
It is also possible to define more than one NUMA node, in which case the
|
|
instance must be split across these nodes.
|
|
|
|
|
|
virtio-net Multiqueue
|
|
---------------------
|
|
|
|
.. versionadded:: 12.0.0 (Liberty)
|
|
|
|
.. versionchanged:: 25.0.0 (Yoga)
|
|
|
|
Support for configuring multiqueue via the ``hw:vif_multiqueue_enabled``
|
|
flavor extra spec was introduced in the Yoga (25.0.0) release.
|
|
|
|
.. important::
|
|
|
|
The functionality described below is currently only supported by the
|
|
libvirt/KVM driver.
|
|
|
|
Virtual NICs using the virtio-net driver support the multiqueue feature. By
|
|
default, these vNICs will only use a single virtio-net TX/RX queue pair,
|
|
meaning guests will not transmit or receive packets in parallel. As a result,
|
|
the scale of the protocol stack in a guest may be restricted as the network
|
|
performance will not scale as the number of vCPUs increases and per-queue data
|
|
processing limits in the underlying vSwitch are encountered. The solution to
|
|
this issue is to enable virtio-net multiqueue, which can allow the guest
|
|
instances to increase the total network throughput by scaling the number of
|
|
receive and transmit queue pairs with CPU count.
|
|
|
|
Multiqueue virtio-net isn't always necessary, but it can provide a significant
|
|
performance benefit when:
|
|
|
|
- Traffic packets are relatively large.
|
|
- The guest is active on many connections at the same time, with traffic
|
|
running between guests, guest to host, or guest to an external system.
|
|
- The number of queues is equal to the number of vCPUs. This is because
|
|
multi-queue support optimizes RX interrupt affinity and TX queue selection in
|
|
order to make a specific queue private to a specific vCPU.
|
|
|
|
However, while the virtio-net multiqueue feature will often provide a welcome
|
|
performance benefit, it has some limitations and therefore should not be
|
|
unconditionally enabled:
|
|
|
|
- Enabling virtio-net multiqueue increases the total network throughput, but in
|
|
parallel it also increases the CPU consumption.
|
|
- Enabling virtio-net multiqueue in the host QEMU config does not enable the
|
|
functionality in the guest OS. The guest OS administrator needs to manually
|
|
turn it on for each guest NIC that requires this feature, using
|
|
:command:`ethtool`.
|
|
- In case the number of vNICs in a guest instance is proportional to the number
|
|
of vCPUs, enabling the multiqueue feature is less important.
|
|
|
|
Having considered these points, multiqueue can be enabled or explicitly
|
|
disabled using either the :nova:extra-spec:`hw:vif_multiqueue_enabled` flavor
|
|
extra spec or equivalent ``hw_vif_multiqueue_enabled`` image metadata property.
|
|
For example, to enable virtio-net multiqueue for a chosen flavor:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ openstack flavor set --property hw:vif_multiqueue_enabled=true $FLAVOR
|
|
|
|
Alternatively, to explicitly disable multiqueue for a chosen image:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ openstack image set --property hw_vif_multiqueue_enabled=false $IMAGE
|
|
|
|
.. note::
|
|
|
|
If both the flavor extra spec and image metadata property are provided,
|
|
their values must match or an error will be raised.
|
|
|
|
Once the guest has started, you must enable multiqueue using
|
|
:command:`ethtool`. For example:
|
|
|
|
.. code-block:: bash
|
|
|
|
$ ethtool -L $devname combined $N
|
|
|
|
where ``$devname`` is the name of the network device, and ``$N`` is the number
|
|
of TX/RX queue pairs to configure corresponding to the number of instance
|
|
vCPUs. Alternatively, you can configure this persistently using udev. For
|
|
example, to configure four TX/RX queue pairs for network device ``eth0``:
|
|
|
|
.. code-block:: bash
|
|
|
|
# cat /etc/udev/rules.d/50-ethtool.rules
|
|
ACTION=="add", SUBSYSTEM=="net", NAME=="eth0", RUN+="/sbin/ethtool -L eth0 combined 4"
|
|
|
|
For more information on this feature, refer to the `original spec`__.
|
|
|
|
.. __: https://specs.openstack.org/openstack/nova-specs/specs/liberty/implemented/libvirt-virtiomq.html
|